Chinese Journal of Orthopaedics ; (12): 744-750, 2023.
Article in Chinese | WPRIM | ID: wpr-993499

ABSTRACT

Objective:To investigate the feasibility and early clinical efficacy of spherical motion axis hinge knee prosthesis to reconstruct distal femoral bone defects.Methods:A retrospective analysis was performed on 16 patients admitted to PLA 960th Hospital and Tianjin Hospital from October 2019 to November 2021, including 8 males and 8 females, with an average age of 43.3±17.8 years (range, 15-71 years). There were 13 patients of primary tumors of the distal femur and 3 patients of postoperative revision of knee joint prostheses. Among the 13 patients with distal femur tumors, there were 6 cases of osteosarcoma, 5 cases of giant cell tumor of bone, 1 case of leiomyosarcoma and 1 case of chondrosarcoma. The reasons for revision after prosthesis replacement in 3 cases were: 2 cases of aseptic loosening after tumor-type prosthesis and 1 case of periphery fracture of surface artificial knee prosthesis. A spherical shaft rotary hinged knee prosthesis was designed and fabricated to reconstruct postoperative femoral defects in 16 patients. Follow up regularly after the operation, recheck the X-ray film to evaluate the lower limb force line, evaluate the quality of life after the operation with the Chinese version of 36-item short-form (SF-36), and evaluate the postoperative limb function with the Musculoskeletal Tumor Society (MSTS) 93 evaluation system.Results:All 16 patients were successfully placed with prostheses, and except for 2 patients undergoing total femoral replacement, the length of bone defects was 18.2±11.7 cm (range, 8.6-47.1 cm) in other 14 patients, and the operation time was 138±19 min (range, 110-170 min), the intraoperative blood loss was 211±118 ml (range, 100-500 ml). The postoperative full length orthostatic X-ray film of the lower limbs showed that the distance between the mechanical axis of the lower limb and the center of the knee joint was 0.1 (0, 0.7) cm in 16 patients, and the hip-knee ankle angle was 179.0°±2.3°(range, 173.3°-182.2°). The patients were followed up for 12-36 months. No prosthesis complications were found in 16 patients. The SF-36 score was 56.7±7.0 (range, 42.7-67.4) for physiological function and 54.1±7.6 (range, 40.5-66.3) for psychological function. The maximum knee flexion angle was 120.0°±15.6° (range, 95°-130°). The MSTS 93 score of 15 patients with tumor was 25.0±1.7 (range, 22-28), including 7 excellent and 8 good. One patient developed liver and lung metastases 10 months after surgery and died 18 months after surgery. The remaining patients, as of the last follow-up, were alive and had no local recurrence or distant metastases. Tumor-free survival time was 25.8±8.4 months (range, 12-36 months).Conclusion:The spherical motion axis hinge knee prosthesis reconstruction for distal femoral bone defects is simple and fast in intraoperative prosthesis installation, and there are no prosthetic related complications during short-term follow-up. The clinical efficacy is satisfactory.

2.
Chinese Journal of Orthopaedics ; (12): 269-276, 2023.
Article in Chinese | WPRIM | ID: wpr-993438

ABSTRACT

Periprosthetic fracture of femur is the most common postoperative complication after total knee arthroplasty (TKA). Risk factors for periprosthetic fractures include female sex, osteoporosis/osteopenia, rheumatoid arthritis, osteoarthritis, neuromuscular disease, cognitive disorder, chronic use of corticosteroids, obesity, advanced age, infection, osteolysis around the prosthesis, knee joint ankyloses, notching of the anterior femoral cortex, etc. According to epidemiological research, the incidence of femoral periprosthetic fractures following TKA ranges from 0.3% to 2.5%. Lewis and Rorabeck classifications, the most commonly used classification of periprosthetic fractures of the femur, introduce the concept of prosthesis loosening and emphasize the ecessity of revision surgery. Other classifications include Su typing, Universal Typing System, and Rhee typing, the latest of which is the Kim typing proposed in 2022. Treatment strategies for periprosthetic femoral fractures after TKA include nonsurgical treatment, external fixation techniques, single-plate fixation, double-plate fixation, intramedullary nail fixation, and revision TKA and distal femur replacement. The purpose of this paper is to better guide the prevention and treatment of periprosthetic fractures after TKA by searching and analyzing relevant literature on periprosthetic fractures after TKA.

3.
Chinese Journal of Orthopaedics ; (12): 155-163, 2023.
Article in Chinese | WPRIM | ID: wpr-993423

ABSTRACT

Objective:To investigate the combination of internal fixation for periprosthetic fractures of the proximal femur (PFFF) after hip arthroplasty.Methods:The data of 58 patients with periprosthetic fractures after hip arthroplasty from May 2008 to March 2022 were retrospectively analyzed, including 31 males and 27 females. The average age was 75.5±18.2 years (range, 35-95 years). There were 39 total hip arthroplasty and 19 hemiarthroplasty; 37 biological prosthesis and 21 cemented prosthesis. Intraoperative periprosthetic fractures occurred in 6 cases and 52 cases postoperatively. Unified classification system (UCS): UCS IV.3A1 type 2 cases, 3A2 type 1 case, 3B1.1 type 19 cases, 3B2.1 type 25 cases, 3B3 type 2 cases, 3C type 9 cases. Fracture site: 3 cases in zone A (greater trochanter), 46 cases in zone B (around the femoral stem), and 9 cases in zone C (distal to the tip of the femoral stem. Internal fixation is composed of primary and secondary fixation, the main fixation method was the cerclage of steel wire or titanium cable, locking compression plate, and locking attachment plate fixation. The secondary fixation method was the cerclage of titanium cable, which was required to cover three zones A, B and C to form an overall balanced fixation. The modified Harris hip scores (mHHS), plate length, working length and screw number of different internal fixation combinations were compared.Results:The follow-up time was 54.2±21.6 months (range, 11-86 months). All patients showed signs of fracture healing at 10.2±1.5 weeks (range, 7-13 weeks) after operation, and bony union was observed at 19.6±1.3 weeks (range, 17-22 weeks) after operation. No delayed union or nonunion was observed. After operation, one case had a stress fracture and was revised with double-plate internal fixation; one case had a failed internal fixation and was revised with double-plate internal fixation and a large allograft bone graft. The mHHS score of UCSIV.3B2.1 group (80.3±4.6) was the lowest at 6 months after operation, and the difference between the groups of different types was statistically significant ( F=256.72, P<0.001). The score of simple internal fixation group (91.6±4.2) was higher than that of revision combined with internal fixation group (81.9±4.1), and the difference was statistically significant ( t=8.32, P<0.001). The plate length and working length were 24.9±2.5 cm and 12.6±1.7 cm for UCS IV.3B1.1, 25.4±2.6 cm and 13.6±1.8 cm for 3B2.1 and 28.1±2.5 cm and 4.9±1.9 cm for 3C, respectively ( F=5.33, P=0.005; F=6.78, P<0.001). The number of screws in zone A was significant difference among different UCS types ( F=52.67, P<0.001); UCS IV.3B1.1 (6.5±2.3) and 3B2.1 (6.7±2.2) were more than 3B3 (3.5±1.5) and 3C (3.7±1.6). The number of screws in zone B was significant difference among different UCS types ( F=42.15, P<0.001); The number of UCS IV.3B1.1 (2.3±1.6) and 3B2.1 (2.8±1.9) were significantly more than that of 3B3 (1.0±0.5) and 3C (1.2±0.6). The number of screws in zone C was significant differences among different UCS types ( F=39.62, P<0.001); The number of UCS IV.3B1.1 (3.8±1.9) and 3B2.1 (3.9±1.7) were more than that of 3B3 (2.0±0.5), the difference was statistically significant ( P<0.05). Conclusion:The function of hip after simple internal fixation of proximal femoral periprosthetic fractures was better than that of those who underwent revision at the same time; the number of screws of UCSIV.B1 and B2 is more than that of B3.

4.
Chinese Journal of Orthopaedic Trauma ; (12): 380-383, 2023.
Article in Chinese | WPRIM | ID: wpr-992722

ABSTRACT

Surgery for periprosthetic fractures (PPF) is one of the most complex procedures in orthopedics. It is difficult, highly risky and extremely challenging, because the patients are usually advanced in age and suffering from essential organ dysfunction, numerous comorbidities, poor overall body condition, poor bone quality combined with osteolysis and even bone loss, and because the surgeons have to apply the concepts and techniques of Modern Orthopedic Trauma and artificial joint revision techniques in fracture fixation and prosthesis revision. This paper expounds on the clinical challenges due to the characteristics of PPF in order to call on clinical surgeons to update their concepts, deal with seriously and standardize their PPF treatment, and effectively improve their efficacy.

5.
Chinese Journal of Orthopaedic Trauma ; (12): 254-259, 2023.
Article in Chinese | WPRIM | ID: wpr-992705

ABSTRACT

Objective:To explore the short-term efficacy of fixation with a 3D printed individualized custom-made plate in the treatment of elderly patients with periprosthetic femoral fracture.Methods:Retrospectively analyzed were the 5 elderly patients with periprosthetic femoral fracture who had been treated by fixation with a 3D printed individualized custom-made plate from January 2022 to July 2022 at Department of Orthopaedics and Traumatology, Beijing Jishuitan Hospital. There were 3 males and 2 females, aged 81, 86, 77, 91 and 87 years, respectively. One left and 4 right limbs were affected. Vancouver classification: type B1 ( n=3), type B2 ( n=1), and type C ( n=1). The time from operation to injury was 5, 6, 10, 5 and 7 days, respectively. Preoperatively, the femur affected, prosthesis and individualized plate with a greater trochanteric hook, loop cable channel and bone-like trabecular microporous structure were custom-made by 3D printing according to 1:1 models. Virtual operations were simulated to formulate surgical protocols. The operation time, length of surgical incision, intraoperative blood loss and transfusion, hospital stay, hip function and complications at the last follow-up were recorded. Results:The 5 patients were followed up for 12, 7, 10, 3 and 6 months, respectively. There were no events of superficial incision or deep prosthesis infection. Respectively, the operation time was 1.8, 1.7, 2.3, 2.0 and 3.3 h; the length of surgical incision 31, 30, 38, 27 and 30 cm; the intraoperative bleeding volume 400, 300, 300, 500 and 600 mL; the length of hospital stay 8, 9, 15, 14 and 11 d. Four patients received intraoperative blood transfusion of 300, 900, 150 and 1, 050 mL, respectively. One patient died of a heart attack 3 months after discharge; another patient developed dyskinesia at the contralateral limb 3 months after discharge due to cerebral infarction and died of recurrent cerebral infarction 7 months after discharge. At the last follow-up, the Harris hip scores of 3 patients were 86, 77 and 69 points, respectively. None of the patients had complications like breakage or loosening of implants.Conclusion:In the treatment of elderly patients with periprosthetic femoral fracture, fixation with a 3D printed individualized custom-made plate may lead to fine limb function and good short-term curative efficacy.

6.
Chinese Journal of Orthopaedics ; (12): 897-904, 2022.
Article in Chinese | WPRIM | ID: wpr-957083

ABSTRACT

Objective:To introduce the surgical method of Ortho-Bridge system (OBS) in the treatment of distal femoral fractures in elderly patients and investigate its clinical effect.Methods:From January 2018 to July 2021, 24 elderly patients who suffered distal femoral fractures were treated with bilateral OBS. There were 8 males and 16 females aging from 62 to 87 years, with an average age of 72.6 years. It included 15 cases of simple distal femoral fractures. According to AO classification, there were one case of A1, two of A2, five of A3, two of C1, three of C2 and two of C3. Nine cases of femoral periprosthetic fractures after total knee arthroplasty (TKA) were classified as type II according to rorabeck's classification. After operation, all patients were guided to perform knee joint functional exercise and to measure the range of motion of the knee joint. Then imaging examinations were used to evaluate the fracture healing and measure the femoral-tibial and femoral angles. The American Hospital for Special Surgery (HSS) knee joint scoring system was used to evaluate the knee function.Results:All 24 patients successfully completed the operation. The operation time was 84-115 min, with an average of 96.6 min; the intraoperative blood loss was 150-335 ml, with an average of 240 ml. All patients were followed up for 8-17 months, with an average of 13.6 months. Except for 1 case of nonunion due to few primary bone grafts, which required secondary bone grafting, the other 23 cases achieved bone union. The healing time was 3.5-6 months, with an average of 4.6 months. At 1, 3, and 6 months after operation and at the last follow-up, the flexion angles of knee were 92.2°±10.2°, 98.6°±13.3°, 106.4°±13.7°, 115.7°±15.3°, and the extension angles were -4.7°±4.1°, -1.2°±4.2°, 0.7°±4.5°, 1.8°±4.6°, respectively; and all differences were statistically significant ( F=17.03 and 12.68, P<0.001). The knee flexion and extension angles at the last follow-up were greater than 1, 3, and 6 months after operation, and the differences were statistically significant ( P<0.001). The femoral-tibial angle was 171.2°±2.4° and 170.7°±3.2°, and the femoral angle was 80.3°±1.7° and 79.6°±2.1°, respectively, at the immediate postoperative and last follow-up, with no significant difference. The HSS scores at 1, 3, 6 months after operation and at the last follow-up were 71.5±7.5, 74.6± 9.3, 78.9±10.4 and 84.7±9.4 respectively, with significant difference ( F=9.17, P<0.001). At the last follow-up, the HSS score was higher than that at 1, 3, and 6 months after the operation, and the differences were statistically significant ( P<0.001), and the knee function was evaluated according to the HSS scoring system: excellent in 12 cases, good in 9, fair in 3, with an excellent and good rate of 88% (21/24). There was no OBS crack or fixation failure in all patients, and no prosthetic loosening and instability occurred in patients with periprosthetic femoral fractures after TKA. Statistical analysis of the data at the last follow-up between the distal femoral fracture group and the periprosthetic femoral fracture group after TKA showed that the knee flexion function and HSS score of the periprosthetic femoral fracture group after TKA (126.8°±3.7°, 92.2±4.1) were both better than the simple distal femur fracture group (108.9°±15.7°, 80.2±8.8). The difference was statistically significant ( t=4.22, 4.52, P<0.05). One patient had incision fat liquefaction and healed after debridement; bone nonunion occurred in 1 case, which healed after iliac bone grafting. Conclusion:Double OBS has a good clinical effect in the treatment of distal femoral fractures in the elderly, especially in patients with periprosthetic femoral fractures after TKA.

7.
Chinese Journal of Trauma ; (12): 909-915, 2022.
Article in Chinese | WPRIM | ID: wpr-956522

ABSTRACT

Objective:To investigate the efficacy of single locked-plate internal fixation combined with autologous iliac bone graft in the treatment of Rorabeck type II periprosthetic distal femural fracture (PDFF) after total knee arthroplasty (TKA).Methods:A retrospective case series study was made on 13 patients suffering from Rorabeck type II PDFF after primary TKA together with severe osteoporosis (T value≤ -2.5 SD) admitted to 940th Hospital of Joint Logistics Support Force of PLA from January 2016 to December 2020, including 4 males and 9 females, aged 65-85 years [(75.2±6.5)years]. All patients were treated with single locked-plate internal fixation combined with autologous iliac bone graft. Anti-osteoporosis and early standardized joint function rehabilitation were undertaken postoperatively. The operation time and intraoperative blood loss were recorded. The range of motion of knee joint was compared before operation, at postoperative 3, 6 and 12 months and at the last follow-up. The Hospital for Special Surgery (HSS) knee score was assessed at postoperative 3, 6 and 12 months and at the last follow-up to evaluate the recovery of knee joint function. The bone mineral density was reexamined at postoperative 6 months and 12 months to evaluate the therapeutic effect of anti-osteoporosis. Complications were detected as well.Results:All patients were followed up for 12-72 months [(43.2±19.9)months]. The operation time was 90-135 minutes [(103.8±12.6)minutes], with the intraoperative blood loss of 100-250 ml [(150.0±45.6)ml]. The range of motion of knee joint was (114.6±7.8)°, (90.4±8.0)°, (97.3±4.8)° and (98.1±6.3)° before operation and at postoperative 3, 6 and 12 months (all P<0.05). The HSS knee score was (80.2±2.2)points, (84.6±2.9)points and (87.3±3.3)points at postoperative 3, 6 and 12 months (all P<0.05). The knee joint function was excellent in 10 patients and good in 3 at postoperative12 months, and the excellent and good rate was 100%. The T value of bone mineral density was (-3.8±0.6)SD, (-3.4±0.6)SD and (-2.9±0.6)SD preoperatively and at postoperative 6 months and 12 months (all P<0.05). One patient experienced nonunion and was cured after secondary autologous iliac bone grafting combined with recombinant human bone morphogenetic protein-2 (rhBMP-2) bone grafting. Three patients developed venous thrombosis of lower limbs and were cured with oral administration of rivaroxaban. One patient had mild knee flexion and extension limitation and was improved after manual release under femoral nerve block anesthesia and subsequent functional rehabilitation. Conclusion:For patients with Rorabeck type II PDFF after TKA, single locked-plate internal fixation combined with autologous iliac bone graft has advantages of short operation time, few intraoperative bleeding, satisfactory knee range of motion and functional recovery as well as significant improvement of bone mineral density.

8.
Chinese Journal of Orthopaedics ; (12): 297-305, 2022.
Article in Chinese | WPRIM | ID: wpr-932835

ABSTRACT

Objective:To evaluate the various wire tension belt ventral compression wiring technologiesfor treating several types of femoral greater trochanter fractures in total hip replacement, according to the different types of greater trochanter of femur fractures.Methods:From March 2013 to June 2019, a total of 1 280 cases of primary total hip arthroplasty were completed in our hospital, 21 patients with greater trochanter fractures were identified in total hip replacement. There were 11 males and 10 females with an average age of 65.81±6.45 years (range 42-76 years). All of them were unilateral. There were 11 cases on the left and 10 cases on the right. There were 11 cases of osteoarthritis secondary to hip dysplasia, 4 cases of hip osteoarthritis, 4 cases of aseptic necrosis of femoral head and 2 cases of femoral neck fracture. Different wire tension belt ventral compression wiring technologies were used for each fracture type. Harris hip function score, Parker activity score, and visual analogue scale (VAS) score of hip pain were evaluated during follow-up. X-ray films were taken to evaluate the fracture healing, prosthesis position, loosening and dislocation.Results:Three new fracture types were proposed: A transverse fracture from the greater trochanter tip to the base (4 cases); B oblique fracture from the greater trochanter tip to the base (according to the fracture line direction, type B was further divided into types B1 (4 cases) and B2 (6 cases); and C fracture line from the greater trochanter to subtrochanteric plane (7 cases). Among the 21 patients, one died at an early stage, two were lost during follow-up, and 18 were followed up for an average of 30.7±7.6 months. In 18 patients, the mean operation time was 110.0±20.0 min, and the mean intraoperative blood loss was 356.9±115.7 ml. The patients' Harris score was 35.26±5.52 at the preoperative, 65.7±6.42 at the 3 months after operation, and 87.75±6.21 at the final follow-up. The difference was statistically significant ( F=377.23, P<0.001). The patients' Parker score was 2.17±0.98 at the preoperative, 5.94±1.11 at the 3 months after operation,and 8.01±0.77 at the final follow-up. The difference was statistically significant ( F=170.96, P<0.001). The patients' VAS score was 6.22±1.11 at the preoperative, 2.61±0.92 at the 3 months after operation, and 1.28±0.67 at the final follow-up. The difference was statistically significant ( F=139.71, P<0.001). Deep vein embolism, heterotopic ossification was noted in one and another patient, respectively. The patient with non-union refused reoperation and had a broken steel wire, lower-limb limp, and no notable pain at the 12-month follow-up examination. Radiographs of 17 patients showed good location of the femoral prosthesis and no chronic pain. Conclusion:Different types of greater trochanter fractures in total hip arthroplasty were proposed, using different wire tension belt ventral compression wiring technologies for the various types of femoral greater trochanter fractures during total hip replacement can improve clinical outcomes.

9.
Chinese Journal of Orthopaedics ; (12): 141-148, 2022.
Article in Chinese | WPRIM | ID: wpr-932816

ABSTRACT

Objective:To investigate the effect of Notch on periprosthetic fracture (PPF) of the femoral prosthesis after primary total knee arthroplasty.Methods:A total of 34 patients diagnosed with femoral PPF at Xi'an Honghui Hospital were retrospectively collected from January 2013 to December 2020. There were 4 males and 30 females with a mean age of 69.2±7.2 years (range, 55-84 years). A total of 102 patients without PPF were matched by gender and age as the control group in a ratio of 1∶3. There were 12 males and 90 females with a mean age of 69.2±7.2 years (range, 55-84 years). The main observation indexes included patients' general information and factors such as coronal alignment, prosthesis design and Notch conditions. Then, subgroup analysis was performed with the depth and Tayside classification of Notch to analyze their effects on PPF.Results:The PPF and control groups were comparable in terms of baseline information such as gender, age, body mass index (BMI), and surgical side. There was no significant difference between the two groups in coronal alignment (χ 2=1.019, P=0.601) and prosthesis design (χ 2=1.545, P=0.214). There was no statistical difference in Notch between the PPF and control groups (χ 2=3.548, P=0.060). The mean length of Notch in the PPF group was 4.5±2.7 mm, compared with 4.9±2.8 mm in the control group, with no significant difference between the two groups ( t=0.732, P=0.465). Further subgroup analysis using a Notch depth of 3 mm as a cut-off and Tayside classification revealed a statistical difference between the two groups (χ 2=11.262, P=0.004; χ 2=14.601, P=0.003). Compared with patients without Notch, the risk of PPF was higher when the depth of Notch exceeded 3 mm, with an odds ratio ( OR) of 4.88 (95% CI: 1.76, 13.51). The incidence of PPF was higher when Notch depth reached Tayside grade 3 or 4. Compared with patients without Notch, the risk of PPF would be 6.99-fold (95% CI: 1.85, 26.32) higher when Notch depth reached grade 3. In female patients, there was a significant difference in Notch status between the PPF and control groups (χ 2=3.956, P=0.047), with a higher risk of PPF in female patients with Notch, OR 2.33 (95% CI: 1.01, 5.43). In patients who underwent right-sided TKA, the risk of PPF was higher in patients with Notch compared to those without Notch (χ 2=5.502, P=0.019), with an OR of 3.58 (95% CI: 1.19, 10.75). Conclusion:The Notch has no significant effect on the femoral PPF after primary total knee arthroplasty. However, the risk of PPF will increase significantly when the Notch depth exceeds 3 mm or is above Tayside grade 3.

10.
Chinese Journal of Orthopaedics ; (12): 47-53, 2022.
Article in Chinese | WPRIM | ID: wpr-932808

ABSTRACT

Objective:To compare the biomechanical parameters of Ortho-Bridge system (OBS) and locking compression plate+locking attachment plate (LCP+LAP) in the fixation of femoral periprosthetic type B1 fracture.Methods:The same periprosthetic type B1 fracture of human femur were made, including simple fracture model and comminuted fracture model, 12 in each. And the simple fracture models were randomly divided into 6 pieces of OBS system fixation group and 6 pieces of LCP+LAP system fixation group, and the complex fracture models were also randomly divided into 6 pieces of OBS system fixation group and 6 pieces of LCP + LAP system fixation group. Then the four groups of models were tested by axial compression and torsion tests, and the stiffness of the models under axial compression and torsion angle of the models under torsion test were collected. The axial compression failure test was carried out to collect the vertical load of the ultimate failure test. The axial stiffness, torsion angle and axial failure load of OBS and LCP+LAP fixed simple and comminuted fractures were statistically analyzed by t test. Results:For the test of fixed simple fracture, there was no significant difference ( t=0.535, P=0.522) in the axial stiffness between the OBS group (868.87±157.14 N) and the LCP+LAP group (904.53±44.76 N), whereas the results of torsion test showed that the LCP+LAP group had a higher torsion angle 7.17°±0.52° than the OBS group 5.45°±0.44° ( t=5.616, P<0.001); When fixing comminuted fractures, the OBS group had a higher axial stiffness (145.33±10.34 N) than the LCP+LAP group (84.15±8.94 N) ( t=10.961, P<0.001), but the LCP+LAP group had a higher torsion angle 7.75°±1.17° than the OBS group 5.23°±0.31° ( t=4.652, P=0.001). Ultimate failure test data showed that the failure pressure of OBS fixed group (4 967.49±132.88 N) was higher than LCP+LAP group (3 967.41±145.16 N) ( t=12.447, P<0.001). In the LCP+LAP group, there was destruction of the contact cortex at the fracture site, while in the OBS group, there was destruction of the contact cortex at the fracture site as well as fractures around the proximal fixation screw. Conclusion:OBS group has similar axial compression resistance to LCP+LAP group, but better torsion resistance than LCP+LAP group when it is used to fix B1 simple fracture around femoral prosthesis. When comminuted fracture is fixed, the axial compression resistance and torsion resistance of OBS group are better than LCP+LAP group. The stress is dispersed during OBS fixation, which can better avoid the failure of internal fixation during early functional exercise.

11.
Chinese Journal of Orthopaedic Trauma ; (12): 798-803, 2021.
Article in Chinese | WPRIM | ID: wpr-910044

ABSTRACT

Objective:To explore mechanical stability of Proximal Humeral Internal Locking Plate System (PHILOS) in the treatment of Vancouver B1 femoral periprosthetic fractures by three-dimensional finite element analysis.Methods:A three-dimensional finite element model of the femur was established by digital medical software (Mimics 21.0, 3-matic12.0, Geomagic12.0 and Hypermesh 2017.0) using the CT data of a femur from a volunteer (male, 34 years old, 173 cm in height and 65 kg in weight). After the femoral trochanter was cut in the femoral models, a femoral stem was implanted. PHILOS fixation (PHILOS group) and Cable-Ready GTR fixation (Cable group) were applied respectively. Loads of 700 N, 1,400 N and 2,100 N were applied to the 2 groups of finite element models. Distributions of Von Mises stress and deformation were investigated in the finite element models of 2 internal fixations; the mechanical stability was compared between the 2 groups of models.Results:The maximum deformation occurred on the femoral ball head in the 2 groups of models. At the load of 2,100 N, the maximum deformation was 3.77 mm in the PHILOS group, larger than 3.58 mm in the Cable group, and the maximum stress peak value in the PHILOS group was 491.54 MPa, about 49.2% lower than that in the Cable group (733.61 MPa). The peak stress in the PHILOS group was mainly distributed on the 4th and 5th fixation ends at the bone plate while the peak stress in the Cable group was mainly distributed on the second titanium cable under the fracture line.Conclusions:Under various loads, both PHILOS fixation and Cable-Ready GTR fixation can provide sufficient mechanical stability. As the peak stress of PHILOS fixation is much lower than that of Cable-Ready GTR fixation, PHILOS can be used as an effective fixation method for Vancouver B1 femoral periprosthetic fractures.

12.
Journal of Medical Biomechanics ; (6): E062-E067, 2021.
Article in Chinese | WPRIM | ID: wpr-904365

ABSTRACT

Objective To evaluate biomechanical strength of locking compression plate (LCP) for fixation of periprosthetic proximal femur fractures (PPFF). Methods Eight matched pairs of Vancouver type B1 adult cadaveric PPFF specimens were fixed with the LCP and the inverted distal femoral less invasive stabilization system (LISS), respectively. Four bicortical locking screws (LCP group) and four unicortical locking screws were used to the length of prosthesis stem, and four double cortical locking screws were used to fix the distal end of the fracture in two groups, the distance from the locking screws to the fracture were also equal. The maximum bending load, maximum bending displacement, bending stiffness, maximum torque, maximum torsional angle and torsional stiffness of two groups in four-point bending test and torsion test were compared and analyzed. Results The maximum bending load, maximum bending displacement and bending stiffness of LCP group were all larger than those of LISS group, but the difference was not statistically significant (P>0.05). The maximum torque, maximum torsional angle and torsional stiffness of LCP group were obviously larger than those of LISS group,and there was a statistical difference between two groups (P<0.05). Conclusions The stiffness of anti-torsion with LCP is significantly better than that with LISS. Consequently, LCP has better biomechanical stability for PPFF.

13.
China Journal of Orthopaedics and Traumatology ; (12): 371-375, 2020.
Article in Chinese | WPRIM | ID: wpr-828289

ABSTRACT

OBJECTIVE@#To evaluate the clinical effect of bridge combined internal fixation system in the treatment of periprosthesis fracture of femur after hip replacement.@*METHODS@#From October 2016 to June 2018, 5 patients of periprosthesis fractures of femur classified type B1 and type C in Vancouver were treated by open reduction and bridging combined with internal fixation, including 2 males and 3 females, with ages of 68, 70, 74, 75, 79 years;type B1 fractures in 4 and type C fractures in 1. Causes of injury:1 case of traffic injury, 4 cases of fall. After the operation, the patients were followed up for complications and fracture healing time by clinical and imaging examination, and Parker activity score was performed.@*RESULTS@#The wounds of 5 patients healed without infection. One case of DVT was confirmed by venography. Five patients were followed up, and the durations were 2, 8, 9, 10, 15 months. One patient died of myocardial infarction 2 months after operation. The average healing time was 12.5 weeks. No loss of reduction or failure of internal fixation was found. Two patients could walk without protection and 1 patient needed to rely on single crutch. One case of periprosthetic fracture had to walk with a single crutch before operation and move indoors with two crutches after operation. The average Parker activity score was 51.8% before operation.@*CONCLUSION@#The bridge combined internal fixation system can be used to fix the fracture after hip replacement with stable femoral prosthesis.


Subject(s)
Aged , Female , Humans , Male , Arthroplasty, Replacement, Hip , Bone Plates , Femoral Fractures , General Surgery , Fracture Fixation, Internal , Fracture Healing , Periprosthetic Fractures , General Surgery , Radiography , Reoperation , Retrospective Studies , Treatment Outcome
14.
Journal of the Korean Fracture Society ; : 52-61, 2020.
Article in Korean | WPRIM | ID: wpr-811279

ABSTRACT

Recently, as the elderly population increases, the incidence of total knee arthroplasty has increased, with a concomitant increase in the frequency of periprosthetic fractures. To determine the treatment plan for fractures, the treatment method should be determined by the patient's age, osteoporosis, fixation status of the implant, and type of fracture. In recent years, operative treatment with reduction and stable fixation, rather than non-operative treatment, was used to promote early joint movement and gait. On the other hand, it is necessary to select an appropriate operative method to reduce complications of surgery, such as nonunion and infection, and expect a good prognosis. In this review, periprosthetic fractures were divided into femur, tibia, and patella fractures, and their causes, risk factors, classification, and treatment are discussed.


Subject(s)
Aged , Humans , Arthroplasty , Arthroplasty, Replacement, Knee , Classification , Femur , Gait , Hand , Incidence , Joints , Knee , Methods , Osteoporosis , Patella , Periprosthetic Fractures , Prognosis , Risk Factors , Tibia
15.
Hip & Pelvis ; : 33-39, 2019.
Article in English | WPRIM | ID: wpr-740449

ABSTRACT

PURPOSE: The difficulty of femoral preparation with supine-position hip hemi-arthroplasty (HA) often leads to intra-operative fractures (IOFs). We aimed to clarify the incidence and types of IOFs in HA for hip fractures performed in the supine and lateral positions. MATERIALS AND METHODS: We retrospectively investigated cases of HA for acute femoral neck fractures from June 2013 to May 2018. We examined the incidence and types of IOFs according to different approaches. We defined supine-position in HA as the supine and hip-hyperextended (over-range) femoral preparation position, and lateral position as the lateral and hip-flexed femoral preparation position. We used a short tapered wedged stem. RESULTS: Supine-position HA was used in 46 patients (23.7%) and lateral-position HA in 148 patients (76.3%). IOFs in supine-position HA occurred in 8 patients (17.4%) and included five Vancouver AGT and three Vancouver B2 fractures. IOFs in lateral-position HA occurred in 3 patients (2.0%) and included one Vancouver AGT and two Vancouver B fractures. Supine-position HA was a risk factor for IOFs (adjusted odds ratio, 9.71; 95% confidence interval, 2.37–39.8; P < 0.01) CONCLUSION: Supine-position in HA is an IOF risk factor and significantly increases the incidence of great trochanter fractures of Vancouver type A.


Subject(s)
Humans , Arthroplasty, Replacement, Hip , Femoral Neck Fractures , Femur , Hemiarthroplasty , Hip Fractures , Hip , Incidence , Minimally Invasive Surgical Procedures , Odds Ratio , Periprosthetic Fractures , Retrospective Studies , Risk Factors
16.
Journal of the Korean Fracture Society ; : 148-156, 2019.
Article in Korean | WPRIM | ID: wpr-766409

ABSTRACT

Periprosthetic acetabular fracture (PAF) is an uncommon complication following hip arthroplasty. However, as the number of people needing hip prostheses continues to rise, the absolute number of PAF is expected to increase as well. These fractures may occur either intraoperatively or postoperatively. Postoperative fractures can be caused by traumatic events or by pathologic conditions related to periacetabular osteolysis. The management of PAF usually depends on the degree of displacement and the stability of the acetabular component. While most of non-displaced fractures can be managed nonoperatively by protected weight bearing, displaced fractures with unstable implants require surgical intervention, which is often technically challenging. This review summarized the latest findings on the epidemiology, the diagnosis, the classification, and the treatment of PAF.


Subject(s)
Acetabulum , Arthroplasty , Classification , Diagnosis , Epidemiology , Hip Prosthesis , Hip , Osteolysis , Periprosthetic Fractures , Weight-Bearing
17.
China Journal of Orthopaedics and Traumatology ; (12): 557-563, 2019.
Article in Chinese | WPRIM | ID: wpr-773878

ABSTRACT

OBJECTIVE@#To explore risk factors of the periprosthetic fracture after hip arthroplasty.@*METHODS@#Potential studies were searched in databases including Pubmed, Embase, Cochrane Library, CNKI as well as Wanfang Database up to November 2018 and references in related literatures. The methodological quality of literature was estimated by Newcastle-Ottawa Scale. Raw data were merged and tested mainly by Revmain 5.3.@*RESULTS@#Seventeen studies in total were appropriate with 90 632 patients. The results revealed that it increased the risk of periprosthetic fracture after hip arthroplasty, including female (=1.62, 95%CI:1.44 to 1.82, =3.@*CONCLUSIONS@#Orthopedics doctors should constantly be cantious about the risk factors including female, revision and diagnosis of rheumatoid arthritis. They are supposed to prevent the periprosthetic fracture by gentle operation during hip arthroplasty and monitoring the functional exercise after operations when the above risk factors occur.


Subject(s)
Female , Humans , Arthroplasty, Replacement, Hip , Femoral Fractures , Periprosthetic Fractures , Reoperation , Risk Factors
18.
China Journal of Orthopaedics and Traumatology ; (12): 686-691, 2019.
Article in Chinese | WPRIM | ID: wpr-773854

ABSTRACT

OBJECTIVE@#To study clinical effects of double plating through different approaches for communicated and obvious osteoporosis periprosthetic femoral fracture following total knee arthroplasty(TKA).@*METHODS@#From July 2010 to June 2017, 21 patients with periprosthetic femoral fracture following TKA were divided into two groups according to operative approach. Fifteen patients in medial and lateral double approaches group, including 5 males and 10 females aged from 63 to 79 years old with an average of (67.2±5.9) years old; 11 patients were type 33-A2 and 4 patients were type 33-A3 according to AO-OTA classification; 12 patients injured by falling down and 3 patients by traffic accident; treated with double plating. Six patients in medial parapatellar approach group, including 3 males and 3 females, aged from 61 to 74 years old with an average of (64.6±6.0) years old; 3 patients were type 33-A2 and 3 patients were type 33-A3 according to AO-OTA classification; 5 patients injured by falling down and 1 patient by traffic accident; treated with double plating. Operative time, blood loss, postoperative drainage, fracture healing time were compared between two groups; HSS score and radiology at 3 and 12 months were compared between two groups.@*RESULTS@#All patients were followed up, and the follow-up time of bilateral approaches group ranged from 12 to 18 months with an average of (14.2±2.6 ) months, while the follow-up time of single approach group ranged from 12 to 16 months with an average of (12.6±2.5) months, and there was no statistical difference between two groups. The operative time and postoperative drainage in bilateral approaches group were (107.2±10.4) min and (213.9±30.4) ml, while in sigle approach group was (95.4±12.8) min and (256.8±34.2) ml, and the differences were significant(0.05). HHS score at 3 and 12 months after operation in bilateral approach were 82.9±5.7 and 84.8±7.1, while in single approach group were 83.6±6.1 and 86.3±6.8; there was no statistical difference in HSS score between two groups(>0.05). According to HSS score at 12 months after operation, 2 cases got excellent results and 13 good in bilateral approaches group; 1 case got excellent result and 4 good and 1 moderate in single approach group; but there was no statistical difference between two groups (χ²=2.625, =0.105). There wase no significant differences in complications between bilateral approaches group(2 cases) and single approach group (1 case)(>0.05).@*CONCLUSIONS@#Double plating technique for communicated and obvious osteoporosis periprosthetic femoral fracture following TKA could obtain good function of knee joint. The medial parapatellar approach has shorter operative time, while the bilateral approaches had less drainage.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Arthroplasty, Replacement, Knee , Femoral Fractures , General Surgery , Fracture Fixation, Internal , Periprosthetic Fractures , General Surgery , Treatment Outcome
19.
Hip & Pelvis ; : 166-173, 2019.
Article in English | WPRIM | ID: wpr-763972

ABSTRACT

PURPOSE: To analyze prognostic factors for the treatment of periprosthetic femoral fractures (PFFs) using the cable-plate construct. MATERIALS AND METHODS: A retrospective review of a consecutive series of 41 PFFs treated by osteosynthesis using the cable-plate system. The mean age of patients was 67.3±12.1 years (range, 42-86 years) and the mean follow-up period was 31.5±11.6 months (range, 12–58 months). Fresh frozen cortical strut allografts were leveraged in three cases for additional stability. Prognostic factors that may potentially affect clinical outcomes were analyzed. RESULTS: At the time of final follow-up, fracture union was obtained in 29 hips (70.7%; Group I) after an average of 13.5 weeks (range, 12–24 weeks). Healing failure after surgical treatment was observed in 12 cases (29.3%; Group II), including delayed union (n=10) cases and nonunion (n=2). Factors significantly associated with fracture union included fracture pattern (P=0.040), plate overlap percentage to stem length (P<0.001) and T-score at the preoperative bone mineral density (P=0.011). Transverse-type fractures around or just distal to a well-fixed femoral stem were observed in six cases (50.0%) of Group II. CONCLUSION: The cable-plate osteosynthesis of PFFs should be performed with caution in transverse-type fractures or in cases with severe osteoporosis. Fixation with sufficient plate overlap to stem length may be critical to prevent healing failure.


Subject(s)
Humans , Allografts , Arthroplasty, Replacement, Hip , Bone Density , Femoral Fractures , Follow-Up Studies , Hip , Osteoporosis , Periprosthetic Fractures , Retrospective Studies
20.
Clinics in Orthopedic Surgery ; : 174-180, 2018.
Article in English | WPRIM | ID: wpr-715565

ABSTRACT

BACKGROUND: Periprosthetic fractures around a total knee replacement (TKR) can be complex and difficult to manage, requiring the surgical expertise of the trauma and arthroplasty surgeon. There are a number of treatment modalities available, each with their own merits and limitations. As data on tumor prosthesis revision in periprosthetic fractures is sparse, this study aims to evaluate the results of revision using a tumor prosthesis and compare them with those of fixation using a locking plate in periprosthetic fractures after TKR. METHODS: This is a retrospective study of 15 patients who underwent either tumor prosthesis revision (n = 7) or locking plate fixation (n = 8) for supracondylar femoral periprosthetic fractures in our hospital from 2009 and 2014. The mean follow-up time for these patients was 44 months. This study's main outcome measures were pain relief, return to premorbid ambulatory function, and complications. RESULTS: The revision and fixation groups saw five versus three patients achieve pain relief (71.4% vs. 37.5%, p = 0.315), and two versus four patients return to their premorbid ambulatory function (28.6% vs. 50%, p = 0.608) at the follow-up, respectively. The mean time to weight-bearing in the revision group and fixation group was 2.9 days and 18.9 weeks, respectively (p = 0.001). There were eight complications seen in the revision group with none requiring reoperation; there were five complications seen in the fixation group, and two required reoperation. CONCLUSIONS: The results of revision TKR using a tumor prosthesis were comparable to those of fixation using a locking plate in periprosthetic fractures after TKR. Tumor prosthesis revision may be considered as a viable alternative to locking plate fixation when indicated.


Subject(s)
Humans , Arthroplasty , Arthroplasty, Replacement, Knee , Follow-Up Studies , Outcome Assessment, Health Care , Periprosthetic Fractures , Prostheses and Implants , Reoperation , Retrospective Studies , Weight-Bearing